Supply. Install. Maintain.
We stay with you.
From total turnkey electrical projects to scheduled AMC for transformers, DG sets, and panels — Actaan Electric is your long-term power infrastructure partner.
Four service areas. One partner.
Total Turnkey Projects
Design to commissioning — one contract, one point of responsibility.
We manage the complete electrical project lifecycle: design, equipment supply (transformers, panels, DG sets, cables, earthing), civil coordination, installation, testing, and commissioning. You deal with one team throughout.
Scope Includes
- ·Electrical design and SLD preparation
- ·Equipment supply (Actaan-manufactured + procured)
- ·HT and LT cable laying and termination
- ·Transformer installation and oil filling
- ·Panel installation and wiring
- ·Earthing and lightning protection
- ·Testing, commissioning, and handover documentation
- ·CEIG / EB inspection coordination
Outcomes
- ✓Single vendor accountability
- ✓Faster project completion
- ✓No coordination gaps between suppliers
- ✓Reduced client management overhead
Transformer Service & AMC
Keep your transformer running at peak efficiency — before a failure forces you to stop.
Transformers that are not regularly maintained suffer insulation degradation, increased losses, and ultimately catastrophic failure. Our transformer AMC keeps your assets in optimal condition with scheduled servicing and predictive diagnostics.
Scope Includes
- ·Periodic visual and thermographic inspection
- ·Oil sampling and BDV (breakdown voltage) testing
- ·Oil filtration and reconditioning
- ·Buchholz relay and protection device testing
- ·Tap changer inspection and lubrication
- ·Winding resistance and IR testing
- ·Silica gel breather replacement
- ·Comprehensive service report after every visit
Outcomes
- ✓Extended transformer life
- ✓Early detection of insulation faults
- ✓Reduced unplanned outages
- ✓Maintained warranty and insurance compliance
Diesel Generator Service & AMC
A DG set that hasn't been tested will fail when you need it.
Scheduled AMC visits cover everything from engine oil and filter changes to full load bank testing — so your DG set starts on the first attempt, every time. Emergency breakdown support included.
Scope Includes
- ·Scheduled preventive maintenance visits
- ·Engine oil, oil filter, air filter, fuel filter replacement
- ·Coolant check and top-up
- ·Battery and starter system inspection
- ·AMF panel testing and calibration
- ·Load bank testing (full load run)
- ·Fuel system and injector check
- ·Emergency breakdown response
Outcomes
- ✓Guaranteed readiness on every mains failure
- ✓Longer engine life through proper servicing
- ✓Lower total cost of ownership
- ✓Priority response for AMC customers
HT & LT Panel Service & AMC
Switchgear that trips unexpectedly costs more than a maintenance contract.
HT and LT panels require regular cleaning, contact inspection, relay testing, and thermal scanning to prevent nuisance tripping and catastrophic faults. Our panel AMC team handles both routine and emergency calls.
Scope Includes
- ·Periodic inspection and cleaning of panels
- ·Breaker contact resistance measurement
- ·Protective relay calibration and testing
- ·Thermographic (IR) scanning of busbars
- ·Tightening of cable terminations and busbar joints
- ·CT/PT testing and accuracy verification
- ·Interlock and safety device verification
- ·Emergency fault attendance and repair
Outcomes
- ✓Reduced nuisance tripping
- ✓Prevention of busbar flash events
- ✓Relay settings documented and up to date
- ✓Audit-ready inspection records
Choose the right maintenance plan.
All AMC plans include a service report after every visit. Pricing is per equipment — contact us for a site-specific proposal.
Standard
4 visits/year
All Basic services + oil/filter changes, load testing, emergency call priority.
Get a QuoteComprehensive
6 visits/year + on-call
All Standard services + dedicated service engineer, 4-hour emergency response SLA.
Get a QuoteThe cost of skipping a service visit.
Every breakdown we prevent saved a customer from a crisis. Here are four they told us about.
Cement Plant, Karnataka
What Happened
A 3.15 MVA transformer had not been serviced in 3 years. BDV tests were skipped. During a summer load peak, insulation failure caused a total shutdown — 11 hours of production loss.
Actaan Response
Annual Transformer AMC with BDV testing, oil filtration, and winding resistance checks. We flagged early insulation degradation six months before it would have failed.
Pharmaceutical Plant, Bengaluru
What Happened
A 500 kVA DG set failed to start during a mains outage at 2 AM — battery had not been inspected for two years. The UPS drained in 12 minutes, triggering a GMP batch failure.
Actaan Response
Comprehensive DG AMC with battery inspection, load bank testing, and 4-hour emergency response SLA. We now test the set quarterly under full load.
Data Centre, Chennai
What Happened
Overheating busbars in a critical LT panel were causing intermittent breaker trips during peak load. Without thermographic scanning, the fault was invisible.
Actaan Response
HT/LT Panel AMC with IR thermographic scanning. We identified a hotspot at a cable lug — re-torqued and re-insulated. Preventive, not reactive.
Hospital Expansion, Hyderabad
What Happened
A 500-bed hospital needed a new transformer, HT panel, LT distribution, and DG set installed in 6 weeks — commissioning before the new block opened was mandatory.
Actaan Response
Total turnkey project: SLD design, Actaan-manufactured transformer + panels, cable laying, CEIG inspection coordination, and commissioning — all in 5.5 weeks.
Ready to protect your power assets?
Share your equipment list and location — we will prepare a customised AMC proposal or project scope within 48 hours.
Request a Service Proposal →